THE PRODUCTS MANUFACTURED:

CONTAINER, BLOCK-MODULE, STATIONARY POWER STATIONS

WELDING ELECTRODES

WALL AND ROOF FRAMELESS "SANDWICH" PANELS

FIBER GLASS HEAT-INSULATING ITEMS (MATS AND PLATES)

ALUMINIUM AND GLASS CONSTRUCTIONS

METALLIC WARM- AND SOUNDPROOFING DOORS

BLOCK MOBILE BUILDING (B-6; B-9; B-12)

 


 

CONTAINER, BLOCK-MODULE, STATIONARY POWER STATIONS

Power station

 

 

Technical characteristics:

Capacity: 1-10 MWt
Electric efficiency: 36 - 42%
General efficiency: 85 - 90%
Tension: 0.4; 6.3; 10.5 KV
Current frequency: 50 Hz
Fuel efficiency: 8500 - 10000 Kj/Kwt
Fuel: natural gas, diesel fuel
Oil consumption: 0.6 g/KWt*hr

Emission of harmful substances:
- NOx when 5% О2: 1.5 g/KWt*hr
- СО when 5% О2: 4.0 g/KWt*hr

Power unit resources:
- before overhaul: 36000 hr
- general technique resources: 100 000 hr

They are aimed for power supply and heating of industrial objects and settlements. Fully automatic, they provide steady parallel functioning with electricity supply network and other similar power supply sources. They are equipped with double-fuel electric units, working on natural gas and diesel fuel.

 

 

WELDING ELECTRODES

OK welding electrodes

 

OK 46.00 (E46a type) – rutile covered, ideal for making short welds, root welds and root passes. Used for manual arc welding at alternate and direct current of load-bearing structures made of carbon and low-alloyed steel with standard ultimate strength up to 500 MPa. Approved by GOST R, VNIIGAS, Register of Shipping.

OK 48.04 (E50a type) - with main cover, used for manual arc welding at direct current of load-bearing structures and pipelines made of carbon and low-alloyed steels with standard ultimate strength up to 539 Mpa (for welding of pipeline seams root layers with standard ultimate strength up to 588 Mpa, provided that it is a possibility of root pass). Approved by GOST R, VNIIGAS, Register of Shipping, Energystroy.

 

OK 53.70 (E50a type) – with main cover, used for manual arc one-way welding at direct current of unturning butts of main oil and gas pipelines, technological pipelines and load-bearing metal structures made of carbon and low-alloyed steels of 50-55 K class. Electrodes of 2,5 mm and 3,0 mm diameter are used for welding of pipe butt seam root layer with standard ultimate strength up to 588 Mpa inclusive. Electrodes of 3,0 mm and 4,0 mm diameter are used for welding of filling and coating layer of pipe seam butts made of steel with standard ultimate strength up to 539 Mpa inclusive. Approved by GOST R, VNIIGAS, Register of Shipping.

OK 74.70 (E60 type) – with main cover, used for manual arc welding at direct current of structures made of cold-resistant low-alloyed steels with standard ultimate strength from 539 to 588 Mpa inclusive (K-60 class), structures of vessels, floating drilling rigs, hoisting machines, mining equipment, filling and coating layer of seams, at welding of main oil and gas pipelines and technological pipelines seams and etc. Approved by GOST R, VNIIGAS, Register of Shipping.

Technical data of OK welding electrodes:

 

Electrode brand

Diameter, mm

Temporary breaking strength, sT, kgf/mm2

Yield point, sT, kgf/mm2

Relative extension, d, %

Impact strength KCV, J/cm2, at t0°C

0

-20

-40

-50

-60

ОК 46.00

2,5; 3,0; 4,0; 5,0

46

38,7

24

47

28

-

-

-

ОК 48.00

2,5; 3,0; 4,0; 5,0

50

42,8

25

-

54

47

-

-

ОК 53.70

2,5; 3,0; 4,0

50

42,8

26

-

85

-

47

-

ОК 74.70

3,0; 4,0

60

54,0

25

-

80

45

-

40

 

SE-03-00 used for welding at reverse polarity direct current of austenitic class stainless steels of 10H17N13M2T and 10H17N13MZT class, as well as 08H18H10T, 08H18H12T class and the like, working at temperatures up to 350° C without heat treatment after welding. Approved by GOST R.

SE-04-00 used for cold welding and for welding at direct current of structures made of high-strength cast iron with globular graphite and gray iron with vermicular graphite, as well as their combinations with steel. For welding of defective parts and welding up of defects in mouldings of high-strength and gray cast-iron; preliminary fusing of the first one or two layers at worn cast-iron parts for the following fusing with special electrodes. Approved by GOST R.

SE-08-00 (E50a type) electrodes with main cover, used for welding at direct current of load-bearing structures made of carbon and low-alloyed structural steels as well as for one-way welding of pipeline seam root layer made of steel with standard ultimate strength up to 588 MPa inclusive. Approved by GOST R.

SE-09H used for fusing of machine wearing parts made of steels and cast iron, working without impact load under conditions of abrasive wear.

SE-10-00 (E60 type) electrodes with main cover, aimed for welding at direct current of load-bearing structures made of carbon and low-alloyed structural steels, working at low temperatures, as well as filling and coating seam at main pipelines welding. Approved by GOST R.

Technical data of SE welding electrodes:

 

Electrode brand

Diameter, mm

Temporary breaking strength, sT, kgf/mm2

Yield point, sT, kgf/mm2 at t=200°C

Yield point, sT, kgf/mm2 at t=3500°C

Relative extension, d, % at t=200°C

Bend angle, degrees

Impact strength, KCV, J/сm2 at t=200°C

SE-03-00

2,5

55

-

-

-

180

-

3,0; 4,0; 5,0

56

37

28

30

-

70

SE-04-00

3,0; 4,0; 5,0

480 (49)

-

-

-

-

-

SE-08-00

2,5, 3,0; 4,0

510 (42,8)

-

-

20

-

200°C = 150 (15,3);
-500°C = 34 (3,5)

SE-081

3,0; 4,0

510 (52)

420 (42,8)

-

20

-

200°C = 160 (16,3);
-500°C = 34 (3,5)

SE-09Н

4,0

-

-

-

-

-

-

SE-10-00

3,0; 4,0

589 (60)

530 (54)

-

20

-

200°C = 150 (15,3);
-400°C = 47 (4,8)
-500°C = 34 (3,5)

 

 

WALL AND ROOF FRAMELESS "SANDWICH" PANELS

Universal panel for walls and roofs

 

Ready to mount, universal panel for walls and roofs, which is used at building of industrial, civil and agricultural objects with indoor designed temperature up to 25°C and indoor relative humidity not higher than 60%.

Maintenance conditions:

- Outdoor temperature - 40°С
- Snow proof load up to 100 kg/m2
- Non-aggressive level of influence on construction
- Can be used in buildings and constructions of 15 m high max. and up to IV wind and V snow zones.

 

Main advantages:

Using material:

Dimensions and weight of "Sandwich" panels:

 

Product type

Length, mm

Mounting width, mm

Thickness, mm

Thickness of edging, mm

Panel mass, 1 m2/kg

Thickness of edging, mm

Panel mass, 1 m2/kg

Roofing panel, TU 5284-002-33580769-99

From 4000 to 6000

1000

135

0.75

26.3

0.8

27.2

165

29.8

30.7

195

33.2

34.1

235

37.9

38.8

Wall panel, TU 5284- 001-33580769-99

60

19.3

20.1

100

23.9

24.7

160

30.8

31.6

200

35.4

36.2

 

Design strength of heat transmission:

 

Panel thickness, mm (Roofing panel)

135

165

195

235

The given strength of heat transmission (m2*°C)/Wt

2.32

2.92

3.88

5.19

Panel thickness, mm (Wall panel)

60

100

160

200

The given strength of heat transmission (m2*°C)/Wt

1.32

2.12

3.66

4.95

 

 

FIBER GLASS HEAT-INSULATING ITEMS (MATS AND PLATES)

Fiber glass heat-insulating mats

 

Heat-insulating items based on staple fiber glass represent modern heat-insulating and sound-proof materials and are produced in the proprietary polyethylene thermocontractable packing in the form of flexible mats (M) and soft and semi-rigid plates (P), that enables to use the items in building structures of any shape and form.

Field of application:

- insulation of flat roofs, inter-floor laps (M-15, P-20)
- insulation of interior partitions and frame panels (M-15, P-20)
- insulation of external walls of one-two-storied buildings, steep roofs (P-20)
- insulation of external walls of many-storied buildings (P-30, P-45)
- insulation of equipment and pipelines (M-15, P-20, P-30)
- impact noise sound-proofing (P-45)

 

Main advantages: flexibility, high elasticity, compression and extension strength, incombustibility, high bio- and chemical resistance, low heat conductivity, temperature resistance (from -60°C to +180°C), good sound-proofing.

Application of heat-insulating materials will allow:

Technical characteristics:

 

Items

Mats (М), GOST 10499-95

Plates (P), GOST 10499-95

Rated density kg/m3

15

20; 25; 30; 35; 45

Thickness, mm

50 - 120

50 - 120

Width, mm

1200

600

Length, mm

1000 - 9000

1200

Coefficient of thermal conductivity, W/m°K

0,040

0,032 - 0,040

 

 

ALUMINIUM AND GLASS CONSTRUCTIONS

Aluminium and glass constructionsAluminium and glass constructionsAluminium and glass constructions

Production's main characteristics – big transparent capacity, air tightness and water resistance, durability, heat- and sound-insulation.

Products are manufactured in accordance with nomenclature and individual projects designed both for completing separate doorways and band-glazing unit.

The products made of aluminium profiles, have atmosphere-resistance coat, painted with powder enamel of different colours.

According to airtightness data, the products of the system can be applied in any climate zone of Russia at building of one or two-stored constructions of various purposes: from residential buildings to industrial objects, schools, health protection objects, cultural and sports constructions.

Glass packs are manufactured from high quality glass. In order to improve heat and sound insulation characteristics, the inner chamber can be filled with argon – the inert gas.

In enclosing structures along with glass-packs a 6 mm single glass or a 25; 28 mm "Sandwich" panel can be installed. All the structures are equipped with ROTO FRANK accessories.

Balcony enclosures made of aluminium profiles help to make your balconies and loggies comfortable and convenient, to protect from noise and dust, and to improve room insulation. The plant manufactures balcony enclosures with both plowing and sliding doors. The enclosures are made in accordance with customer’s specific dimensions.

 

 

METALLIC WARM- AND SOUNDPROOFING DOORS

Metallic door with heat-insulation

Metallic doors with heat-insulation can be manufactured in both blind and glass variants. By agreement with a customer it is possible to make non-standard doors and also to paint them automatically with powder enamel. Edging material – 0,6-1 mm thick galvanized steel sheet. The door-frame is made of 2 mm steel. Warm-and sound proofing agent is wool of staple glass fiber, which is fixed to the edging with polyurithane glue.

Specifications:

 

Dimension type

Doorway overall dimensions

Thickness of a flat, mm

Width, mm

Height, mm

1

21-7 (S) single

670

2071

50

2

21-8 (S)

770

2071

50

3

21-9 (S)

870

2071

50

4

21-10 (S)

970

2071

50

5

21-12 (S)

1170

2071

50

6

21-13 (B) bivalve

1272

2071

50

7

24-10 (S)

970

2371

50

8

24-12 (S)

1170

2371

50

9

24-15 (B) bivalve

1472

2371

50

10

24-19 (B)

1872

2371

50

 

 

BLOCK MOBILE BUILDING (B-6; B-9; B-12)

Block mobile building

 

Block-boxes are aimed for erection of production buildings, used in various branches of industry.

Made in the form of thermocontainer block-box provides climate stability both for operating personnel and for equipment placed in it. It is protected against breaking in and robbery. Block-boxes are manufactured both serially and under an individual order.

The building structure is designed for operation in the areas of cold and temperate climate in accordance with GOST 16350-80 with design outdoor temperature up to -50°C, normal snow load up to 200 kgf/m2 and seismicity up to 9 points.

The basic complete set of block-box consists of:

- cable input, cable duct, incorporated units for floor cupboards, table;
- board with power switching equipment;
- air duct;
- oil heater – 1 piece;
- fire-extinguisher;
- first-aid set;
- rack;
- working table and lighting (electric luminaire, switch);
- open wiring socket – 2 pcs.;
- pocket for documents;
- block-box door, equipped with door-knobs and hasp lock.

The building foundations are designed for technological load up to 800 kgf/m2. The buildings are used for all production categories.

The block is used as a detached box and in the structure of building, joining both at short and long sides.

The buildings are manufactured from blocks on foundation prepared.

Block-boxes are delivered to the destination site completely prefabricated.

Block-box has a cross-section to the maximum close to outline of load size to a railway platform.

 


UP

Main page Zapsibgazprom >