OAO Gazprom
Zapsibgazprom

 

Catalogue >

Main page Zapsibgazprom >

 

THE PRODUCTS MANUFACTURED:

AUTOMATIC VAPOR BOILER ROOMS

STEEL WATER HEATING BOILERS

AUTOMATIC CONTAINER BOILER ROOMS

GGB GAS DOMESTIC BURNER

TYPE E VAPOR BOILERS

"SIBIRYAK" SERIES GAS BOILERS

GAS INFRARED RADIATORS

 


 

AUTOMATIC VAPOR BOILER ROOMS

The automatic boiler rooms are destined for production of saturated vapor, used for heating and hot water supply to dwellings, production premises and social buildings, as well as for technological needs in the oil and gas industry.

Application area:

Technical characteristics:

 

Denomination

Vapor boiler room capacity 1 t/hr

Vapor boiler room capacity 3,1 t/hr

Nominal output, t/hr

1

3,2

Vapor consumption for technological needs, t/hr

0,7

2,44

Vapor consumption for boiler blocks rooms heating, t/hr

0,038

0,1

Vapor consumption for pre-heating of the liquid fuel, t/hr

0,08

0,1

Vapor consumption for pre-heating of the supply water, t/hr

0,15

0,4

Heat carrier

Saturated vapor with absolute pressure up to 0,9 MPa

Saturated vapor with absolute pressure up to 0,9 MPa

Condensate losses by exterior users, %

100

100

Fuel type:
Liquid
Gas

 
GOST 105-99, heavy oil fuel
Natural gas

 
GOST 105-99, heavy oil fuel
Natural gas

Raw water consumption, m3/hr

1

5,8

Chemically treated water consumption, m3/hr

1

3,2

Fuel consumption, kg/hr:
Heavy oil M100
Natural gas

 
64
40

 
180
129

Installed electric power, KWt

18,2

45,2

Estimated power, KWt

11,6

30

 

 

STEEL WATER HEATING BOILERS

Automatic stationary KSV water heating boilerAutomatic stationary KSV water heating boiler

The automatic stationary KSV two-stroke and three-stroke heat–pipe smoke-consuming water heating boilers are destined for heating and hot water supply to dwellings, apartments, industrial and social buildings, for warehouses and auxiliary spaces (structures).

Main advantages:

Technical characteristics of the KSV water heating boilers:

 

Denomination

KSV-0,1

KSV-0,25

KSV-0,5

KSV-1,0

KSV-2,0

KSV-3,0

KSV-5.0

Nominal heat productivity, MWt (Gcal/hr)

1,0/0,86

0,25/0,22

0,5/0,43

1,0/0,86

2,0/1,72

3,0/2,58

5,04/4,31

Boiler efficiency, %

91

91

92

92

92

92

92

Minimum input t °C

70

70

70

70

70

70

70

Minimum output t °C

115

115

115

115

115

115

115

Hydraulic resistance, MPa (kg/cm2), not more

0,01/0,1

0,01/0,1

0,01/0,1

0,01/0,1

0,01/0,1

0,01/0,1

0,01/0,1

 

 

AUTOMATIC CONTAINER BOILER ROOMS

Automatic container boiler roomAutomatic container boiler room inside

The boiler room is destined for the central heat and hot water supply to the industrial premises, administrative buildings, dwellings and other objects.

The complete boiler room manufactured at the plant is composed of block-boxes, made of thermal isolating sandwich panels, where the heat water boilers with burners and other corresponding equipment, such as the pumping unit, hot water supply system, water pretreatment plant are installed.

The "Thermal" boiler room is highly economic. It is environment friendly and answers the modern requirements of the industrial aesthetics. The boiler room is developed so that the maximum manufacture and mounting is made at plant conditions and to minimize the construction and installation works at site.

"Thermal" boiler rooms technical characteristics:

 

Denomination

Thermal 500

Thermal 800

Thermal 1000

Thermal 2000

Thermal 4000

Thermal 6000

Thermal 9000

Thermal 12000

Heat productivity, Mwt

0,5

0,8

1,0

2,0

4,0

6,0

9,0

10,0

Qty boilers, unit/Mwt

2 x 0,25

2 x 0,4

2 x 0,5

2 x 1,0

2 x 2,0

2 x 3,0

3 x 3,0

4 x 3,0

Boiler efficiency, %

92

92

92

92

92

92

92

92

Heat carrier- water with the input water t °C

70

70

70

70

70

70

70

70

Heat carrier- water with the output water t °C

115

115

115

115

115

115

115

115

Heat carrier input pressure, bar

1

1

1

1

1

1

1

1

Heat carrier output pressure, bar

4

4

4

4

4

4

4

 

Available head in the heating network, m

30

30

30

30

30

30

30

30

Fuel consumption (natural gas), m3/hr

64

120

180

240

480

720

1080

1440

Room category

G

G

G

G

G

G

G

G

Room class by Electrical devices installation rules

Norm.

Norm.

Norm.

Norm.

Norm.

Norm.

Norm.

Norm.

Length, m

7

9

12

12

12

12

12

12

Width, m

3,1

3,1

3,1

6,2

6,2

9,3

12,42

15,5

Height, m

3,9

3,9

3,9

3,9

3,9

3,9

3,9

3,9

Block weight for transportation, kg

13380

21100

23500

47300

63800

80000

157700

193000

Total consumed electric power, KWt

20,2

47

51,5

67,32

97,64

173

255

345

Total estimated consumed electric power, KWt

7,75

20,2

37,1

37,1

79,68

100

179

256

Heated area at estimated t=370°C m2 (for room 2,5m high)

4800

9600

12000

24000

48000

72000

108000

144000

 

 

GGB GAS DOMESTIC BURNER

GGB gas domestic burner

 

The GGB burner electric appliance is destined to be installed in domestic gas water heating devices (boilers). It works on natural or liquefied gas. The automatic devices installed on burners control the draught in the chimney and the flame on burners and ensure the spaces heating processes regulation.

Technical characteristics:

Nominal heat productivity: 10-30 KWt

Gas working pressure in the network, KPa (natural gas): 1.3-2.0

Gas working pressure in the network, KPa (liquefied gas): 3.0

Gas consumption at nominal output: 2.5 m3/hr

Efficiency, not less than: 81.0 %

 

 

 

TYPE E VAPOR BOILERS

The automatic stationary vapor two and three-strokes heat-pipe type E boilers are destined to produce vapor, used for heating and hot water supply of dwellings, industrial and social buildings, as well as for technological needs.

 

Denomination

E-0,5-0,9GM

E-1,6-0,9GM

E- 2,5-0,9GM

Two-stroke

Three-stroke

Three-stroke

Nominal output, t/hr

0,5

1,6

2,5

Efficiency, %, natural gas

89,1

89

89,2

M100 Sulfur heavy oil

86,3

86

87,3

Working pressure MPa (sgf/cm2)

0,8

0,8

0,8

Nominal input liquid temperature, °C

50

50

50

Output vapor nominal temperature, °C

174,5

174,5

174,5

Fuel consumption:
Natural gas
M100 sulfur heavy oil

 
218
284

 
233,9
305,2

 
215
262

Liquid volume, m3

1,13

5,3

8,8

Heated surface, m2

10,18

53,04

102,8

Boiler mass, kg

1752

8450

11090

Boiler dimensions, m

2,8 x 1,78 x 1,48

4,81 x 2,45 x 2,17

5,13 x 2,61 x 2,51

Temperature of the boiler protecting surface, 0°C, not more

45

45

45

Average life time, years, not less

15

15

15

 

 

"SIBIRYAK" SERIES GAS BOILERS

The "Sibiryak" series gas boilerThe boilers are wall-mounted

The "Sibiryak" series gas boilers are manufactured as having one function and two functions. They are destined to heat different area spaces by closed or open heating system, as well as to heat sanitary water. The articles exterior boasts high designer features.

The boilers are wall-mounted, which gives modern look spaces where they are installed. The frame is executed from sheet steel, and covered consequently with white paint. The pumps are installed in boilers for forced water circulation, which may last up to 15 years when operated correctly.

The boilers are safe in operation, have 6 independent protection levels:

The functioning of the boiler is controlled by an electronic panel depending on:

The articles are certified and allowed for use by Gosgortechnadzor of Russia.

Technical characteristics:

 

Article denomination

Efficiency, not less than, %

Gas working pressure in the network, KPa

Gas consumption at nominal output

Nominal heat productivity, KWt

Heated area, m3

natural

liquefied

natural gas, m3/hr

liquefied gas, kg/hr

GCO 29-06А

88,0

2,0

3,5

3,5

2,5

16,0 - 29,0

Up to 300

GCO 10-15

88,0

1,3 - 2,0

-

1,1

0,6

4,0 - 10,0

From 40 up to 100

GCO 24-06

88,0

2,0

3,0

2,8

1,8

24,0

Up to 250

 

 

GAS INFRARED RADIATORS

The gas infrared radiator "Clear"The gas infrared radiator "Dark"

The use of the infrared gas radiators is the most efficient method to heat the industrial premises with the ceilings not less than 4 m high.

The gas infrared radiator (GIR) is the device, which heat radiating surface is heated by the burning of the gas. The gas supplied to the radiator is burnt inside the ceramic plates ("Clear" GIR) and pipes ("Dark" GIR).

 

Index

L- shaped radiators

U-shaped radiators

15L

20L

30L

40L

50L

15U

20U

30U

40U

50U

Nominal heat rating

15

19

29

39

49

15

19

29

39

49

Maximum gas pressure in front of pressure regulator not more than, (Pa).

6000

6000

Gas expense at nominal rating
- For natural gas, (м3/h)
- For liquefied gas, (kg)

 
1,5

 
1,91

 
2,91

 
3,91

 
4,91

 
1,5

 
1,91

 
2,91

 
3,91

 
4,91

Heating surface temperature

400

400

Nitrogen oxide content in dry straight burning products (mg/m3), not more than

210

210

Carbon oxide content in dry straight burning products
(% per volume) not more than

0,05

0,05

Mass, (kg) not more than

56

56

79

102

125

54

54

92

92

132

Overall dimensions, (mm)
- length
- width
- height

 
6705

 
6705

 
9755

 
12805

 
14230

 
3583

 
3583

 
6634

 
6634

 
9614

 


UP