UNIVERSAL COPPER SULPHATE ELECTRODE (UCSE-1)
HOUSEHOLD CYLINDER 3-5-3-K (GOST 15860)
WELDED STEEL CYLINDERS FOR LIQUEFIED GAS FOR PRESSURE UP TO 1,6 MPa, USED IN AUTOMOBILES
POWDER-TYPE PORTABLE FIRE EXTINGUISHERS PE-3 (G), PE-6(G), PE-10(G), PE-10 (P)
POWDER-TYPE MOVABLE FIRE EXTINGUISHERS PE-50(P)
MODULES OF POWDER-TYPE FIRE-FIGHTING MPF (H)-100(50)-KD2-3-Y2
UNIVERSAL COPPER SULPHATE ELECTRODE (UCSE-1)
Universal Copper Sulphate Electrode (UCSE-1) is used as an electrode of comparison in measuring ultimate potential difference between underground structures protected by method of cathode polarization and the earth.
UCSE-1 is adapted for operation in all climatic areas at an ambient temperature from -10° C to + 40° C.
The contact electric resistance of the unit is within 0,5-10,0 kOhm.
The potential in relation to chlorine silver electrode 120 ± 30 mV.
PARTS OF PIPELINES
The enterprise produces parts for pipelines as follows:
HOUSEHOLD CYLINDER 3-5-3-K (GOST 15860)
Welded steel cylinder with lock device and with volume of 50 liters for pressure up to 1,6 MPa is adapted for transportation and storage of liquefied hydrocarbonate gases (propane, butane and their mixes).
WELDED STEEL CYLINDERS FOR LIQUEFIED GAS FOR PRESSURE UP TO 1,6 MPa, USED IN AUTOMOBILES
Technical Conditions 3695-101-00153784-94.
Welded steel cylinders with volume of 45, 50, 65 liters for pressure up to 1,6 MPa are adapted for transportation and storage of gases (propane, butane and their mixes) in cars equipped with gas installations.
Cylinders AG-45, AG-50 are used for cars of VAZ and MOSKVICH of all modifications.
Cylinder AG-65 is used for cars of GAZ of all modifications.
Specifications:
|
Type |
AG-45 |
AG-50 |
AG-65 |
|
Total Volume, dm3, not less than |
45 |
50 |
65 |
|
Useful Volume, m3, not less than |
36 |
40 |
52 |
|
Diameter, mm |
299 +3 |
299 +3 |
299 +3 |
|
Length, mm |
750 |
816 |
1023 |
|
Mass, kg |
19,5 |
21 |
25,5 |
POWDER-TYPE PORTABLE FIRE EXTINGUISHERS PE-3 (G), PE-6(G), PE-10(G), PE-10 (P)
In Oil and gas industry Powder-type Portable Fire Extinguishers are adapted to extinguish inflammations and fire of A, B, C classes as well as electrical installations operating with voltage of 1000 V.
These extinguishers are also used in other economic and industrial structures, for example to complete motor and tractor engineering and for household use.
The extinguishers are not adapted to fight the inflammations of substances burning of which can occur without access of air.
Climatic modification Y2 is in accordance with GOST 15150-69.
Technical characteristics are in accordance with Technical Conditions 4854-206-00153784-97.
Specifications:
|
Denomination of index |
PE-3 (G) |
PE-6 (G) |
PE-10 (G) |
PE-10 (P) |
|
Volume of extinguisher, l (liters) |
3±0,1 |
6±0,15 |
10±0,3 |
10±0,3 |
|
OTB Mass, kg |
2±0,1 |
4,5±0,2 |
7±0,3 |
8±0,4 |
|
Fire extinguishing capacity:
|
|
|
|
|
|
Operating pressure in body of fire extinguisher at an ambient temperature of 20° C:
|
|
|
|
|
|
Actuation time, s (seconds), not more than |
5 |
5 |
5 |
2 |
|
Duration of supply of OTB, s (seconds), not less than |
5-8 |
6 |
10 |
14 |
|
Length of jet, m, not less than |
3 |
3,5 |
6 |
7 |
|
Overall dimensions, m:
|
|
|
|
|
|
Total mass of fire extinguisher, kg, not more than |
6 |
8 |
16 |
18 |
|
Type of fire extinguisher |
Gas generating |
Gas generating |
Gas generating |
Rumping |
|
Operation period up to writing off, years |
10 |
10 |
10 |
10 |
A set of supply: fire extinguisher as a unit, package, certificate.
POWDER-TYPE MOVABLE FIRE EXTINGUISHERS PE-50(P)
In Oil and gas industry and in other economic and industrial structures Powder-type Portable Fire Extinguishers PE-50(P) are adapted to extinguish inflammations and fire of A, B, C classes as well as electrical installations operating with voltage of 1000 V.
The extinguishers are not adapted to fight the inflammations of substances burning of which can occur without access of air. Climatic modification Y2 is in accordance with GOST 15150-69.
Technical characteristics are in accordance with Technical Conditions 4854-206-00153784-97.
- Volume of extinguisher: 50±1 l (liters)
- OTB Mass: 35±1,5 kg
- Fire extinguishing capacity class A (class B): 6A (233B)
- Operating pressure in body of fire extinguisher at an ambient temperature of 20° C: minimum - 1,6 MPa, maximum - 1,76 MPa
- Actuation time, s (seconds), not more than: 5
- Duration of supply of OTB, s (seconds), not less than: 25
A set of supply: fire extinguisher as a unit, certificate.
MODULES OF POWDER-TYPE FIRE-FIGHTING MPF (H)-100(50)-KD2-3-Y2
Technical Conditions 4854-201-00153784-98.
Modules of powder-type fire-fighting MPF (H) (further as "Modules") are adapted for application in fire-fighting automatic installations to supply fire extinguishing powder to the object within fire-fighting process.
In economic and industrial structures the modules are also used for localization of fire of A, B, C class and electric installations operating with voltage not more than 1000 V in moderate climatic conditions (category-2, according to GOST 15150), but for operation at temperatures from -50°C to +50°C; with relative humidity up to 80% - at temperature 20°C.
The modules are not adapted to fight the inflammations of substances burning of which can occur without access of air.
The modules are explosion-proof, the rate of explosion protection is I ExqII T6 according to GOST 22782.2.
Specifications:
|
Denomination of index |
MPF (H)-50 |
MPF (H)-100 |
|
Volume of Module, l (liters) |
50-1,0 |
100-2,0 |
|
Mass of one of the types of fire extinguishing powder, kg |
35-2,0 |
70-4,0 |
|
Operating gas |
Air (nitrogen) |
Air (nitrogen) |
|
Operating pressure, MPa (kgf/sm2) |
1,6±0,2 (16±2) |
1,6±0,2 (16±2) |
|
Fire extinguishing capacity:
|
|
|
|
Speed of response, s (seconds), not more than |
5 |
5 |
|
Operating time, s (seconds) |
20±2 |
20±2 |
|
Mass of the residual fire extinguishing powder, %, not more than |
15 |
15 |
|
Power Voltage, V |
13 |
13 |
|
Operation Voltage, V |
11 |
11 |
|
Type of current |
Direct |
Direct |
|
Strength of current, minimum, A |
0,4 |
0,4 |
|
Duration of starting pulse, s, not less than |
2 |
2 |
|
Mass of loaded module, kg, not more than |
80 |
160 |
|
Overall dimensions, mm, not more than
|
|
|
|
Module operation period with reloaded powder, displacing gas and change of gaskets, years. |
10 |
10 |
A set of supply: fire extinguisher as a unit, sprayers, certificate. Montage, binding, connection and operation of module is made in accordance with design plans and specification by a specialized company which has a license allowing to carry out such work.