OAO Gazprom
Kubangazprom

 

Catalogue >

 

KUBANGAZPROM

 

Address: Russia, 350051, Krasnodar, 53 Shosse Neftyannikov str.

Tel.: +7 (8612) 24-13-71, 24-08-68; Fax: +7 (8612) 24-55-38

E-mail: rnto@kuban.gazprom.ru

 

THE PRODUCTS MANUFACTURED:

UNIVERSAL COPPER SULPHATE ELECTRODE (UCSE-1)

PARTS OF PIPELINES

HOUSEHOLD CYLINDER 3-5-3-K (GOST 15860)

WELDED STEEL CYLINDERS FOR LIQUEFIED GAS FOR PRESSURE UP TO 1,6 MPa, USED IN AUTOMOBILES

POWDER-TYPE PORTABLE FIRE EXTINGUISHERS PE-3 (G), PE-6(G), PE-10(G), PE-10 (P)

POWDER-TYPE MOVABLE FIRE EXTINGUISHERS PE-50(P)

MODULES OF POWDER-TYPE FIRE-FIGHTING MPF (H)-100(50)-KD2-3-Y2

 


 

UNIVERSAL COPPER SULPHATE ELECTRODE (UCSE-1)

Universal Copper Sulphate Electrode (UCSE-1)

 

Universal Copper Sulphate Electrode (UCSE-1) is used as an electrode of comparison in measuring ultimate potential difference between underground structures protected by method of cathode polarization and the earth.

UCSE-1 is adapted for operation in all climatic areas at an ambient temperature from -10° C to + 40° C.

The contact electric resistance of the unit is within 0,5-10,0 kOhm.

The potential in relation to chlorine silver electrode 120 ± 30 mV.

 

 

PARTS OF PIPELINES

Steeply curved tapsWelded (without joints) steel concentric junctionsFlat steel flanges

The enterprise produces parts for pipelines as follows:

 

 

HOUSEHOLD CYLINDER 3-5-3-K (GOST 15860)

Welded steel cylinder with lock device

Welded steel cylinder with lock device and with volume of 50 liters for pressure up to 1,6 MPa is adapted for transportation and storage of liquefied hydrocarbonate gases (propane, butane and their mixes).

 

 

WELDED STEEL CYLINDERS FOR LIQUEFIED GAS FOR PRESSURE UP TO 1,6 MPa, USED IN AUTOMOBILES

Welded steel cylinders for liquefied gas

 

Technical Conditions 3695-101-00153784-94.

Welded steel cylinders with volume of 45, 50, 65 liters for pressure up to 1,6 MPa are adapted for transportation and storage of gases (propane, butane and their mixes) in cars equipped with gas installations.

Cylinders AG-45, AG-50 are used for cars of VAZ and MOSKVICH of all modifications.

Cylinder AG-65 is used for cars of GAZ of all modifications.

 

Specifications:

 

Type

AG-45

AG-50

AG-65

Total Volume, dm3, not less than

45

50

65

Useful Volume, m3, not less than

36

40

52

Diameter, mm

299 +3

299 +3

299 +3

Length, mm

750

816

1023

Mass, kg

19,5

21

25,5

 

 

POWDER-TYPE PORTABLE FIRE EXTINGUISHERS PE-3 (G), PE-6(G), PE-10(G), PE-10 (P)

Powder-type portable fire extinguishers

 

In Oil and gas industry Powder-type Portable Fire Extinguishers are adapted to extinguish inflammations and fire of A, B, C classes as well as electrical installations operating with voltage of 1000 V.

These extinguishers are also used in other economic and industrial structures, for example to complete motor and tractor engineering and for household use.

The extinguishers are not adapted to fight the inflammations of substances burning of which can occur without access of air.

Climatic modification Y2 is in accordance with GOST 15150-69.

Technical characteristics are in accordance with Technical Conditions 4854-206-00153784-97.

 

Specifications:

 

Denomination of index

PE-3 (G)

PE-6 (G)

PE-10 (G)

PE-10 (P)

Volume of extinguisher, l (liters)

3±0,1

6±0,15

10±0,3

10±0,3

OTB Mass, kg

2±0,1

4,5±0,2

7±0,3

8±0,4

Fire extinguishing capacity:
- class A
- class B

 
2A
34B

 
2A
55B

 
4A
144B

 
4A
144B

Operating pressure in body of fire extinguisher at an ambient temperature of 20° C:
- minimum, MPa
- maximum, MPa

 
0,75
0,85

 
0,9
1,0

 
0,9
1,0

 
1,0
1,2

Actuation time, s (seconds), not more than

5

5

5

2

Duration of supply of OTB, s (seconds), not less than

5-8

6

10

14

Length of jet, m, not less than

3

3,5

6

7

Overall dimensions, m:
- length
- width
- height

 
220
100
310

 
350
150
350

 
390
190
390

 
430
200
420

Total mass of fire extinguisher, kg, not more than

6

8

16

18

Type of fire extinguisher

Gas generating

Gas generating

Gas generating

Rumping

Operation period up to writing off, years

10

10

10

10

A set of supply: fire extinguisher as a unit, package, certificate.

 

 

POWDER-TYPE MOVABLE FIRE EXTINGUISHERS PE-50(P)

Powder-type portable fire extinguisher

 

In Oil and gas industry and in other economic and industrial structures Powder-type Portable Fire Extinguishers PE-50(P) are adapted to extinguish inflammations and fire of A, B, C classes as well as electrical installations operating with voltage of 1000 V.

The extinguishers are not adapted to fight the inflammations of substances burning of which can occur without access of air. Climatic modification Y2 is in accordance with GOST 15150-69.

Technical characteristics are in accordance with Technical Conditions 4854-206-00153784-97.

- Volume of extinguisher: 50±1 l (liters)
- OTB Mass: 35±1,5 kg
- Fire extinguishing capacity class A (class B): 6A (233B)
- Operating pressure in body of fire extinguisher at an ambient temperature of 20° C: minimum - 1,6 MPa, maximum - 1,76 MPa
- Actuation time, s (seconds), not more than: 5
- Duration of supply of OTB, s (seconds), not less than: 25

A set of supply: fire extinguisher as a unit, certificate.

 

 

MODULES OF POWDER-TYPE FIRE-FIGHTING MPF (H)-100(50)-KD2-3-Y2

Module of powder-type fire-fighting

 

Technical Conditions 4854-201-00153784-98.

Modules of powder-type fire-fighting MPF (H) (further as "Modules") are adapted for application in fire-fighting automatic installations to supply fire extinguishing powder to the object within fire-fighting process.

In economic and industrial structures the modules are also used for localization of fire of A, B, C class and electric installations operating with voltage not more than 1000 V in moderate climatic conditions (category-2, according to GOST 15150), but for operation at temperatures from -50°C to +50°C; with relative humidity up to 80% - at temperature 20°C.

The modules are not adapted to fight the inflammations of substances burning of which can occur without access of air.

The modules are explosion-proof, the rate of explosion protection is I ExqII T6 according to GOST 22782.2.

 

Specifications:

 

Denomination of index

MPF (H)-50

MPF (H)-100

Volume of Module, l (liters)

50-1,0

100-2,0

Mass of one of the types of fire extinguishing powder, kg

35-2,0

70-4,0

Operating gas

Air (nitrogen)

Air (nitrogen)

Operating pressure, MPa (kgf/sm2)

1,6±0,2 (16±2)

1,6±0,2 (16±2)

Fire extinguishing capacity:
- protected area, m2
- protected volume, m3
- maximum rank of fire as per “B” class

 
15
35
55 B

 
40
80
144 B

Speed of response, s (seconds), not more than

5

5

Operating time, s (seconds)

20±2

20±2

Mass of the residual fire extinguishing powder, %, not more than

15

15

Power Voltage, V

13

13

Operation Voltage, V

11

11

Type of current

Direct

Direct

Strength of current, minimum, A

0,4

0,4

Duration of starting pulse, s, not less than

2

2

Mass of loaded module, kg, not more than

80

160

Overall dimensions, mm, not more than
- length
- width
- height

 
400
550
1050

 
800
550
1050

Module operation period with reloaded powder, displacing gas and change of gaskets, years.

10

10

 

A set of supply: fire extinguisher as a unit, sprayers, certificate. Montage, binding, connection and operation of module is made in accordance with design plans and specification by a specialized company which has a license allowing to carry out such work.

 


UP